Fluid - Structure - Soil Interaction of Cylindrical Liquid Storage Tank Subjected to Horizontal Earthquake Loading
|
Kamila Kotrasova,
Slavka Harabinova,
Eva Panulinova,
Iveta Hegedusova,
M. Iman Khodakarami
|
Transactions of the VSB - Technical University of Ostrava, Civil Engineering Series |
2019, Volume 19, Issue 1, Pages 8-14
|
Doi: 10.35181/tces-2019-0002
|
Shallow founded tanks are strategic structures used to store a variety of kind of liquids. The fluid develops hydrodynamic effect on solid domain of container during an earthquake. This paper provides the theoretical background for numerical model on seismic response of fluid-structure-soil interaction. The Finite Element Method (FEM) was used for seismic response of shallow founded cylindrical container. The Fluid-Structure-Soil interaction of shallow founded tank was analysed according to theories of I. Limit States - the ultimate limit state (ULS) and II. Limit States - the serviceability limit state (SLS) pursuant to EN 1997-1. Summary of the results: the maximum rotation of foundation is growing with the reduction of the stiffness of the subsoil and the vertical and horizontal bearing capacity depends on the strength properties of the subsoil.
|