Geophysical Survey Using for Evaluation of Moisture Conditions in Non-saturated Zone
|
Vojtech Gajdos,
Andrej Mojzes,
Viliam Nagy,
Kamil Rozimant,
Vlasta Stekauerova
|
Transactions of the VSB - Technical University of Ostrava, Civil Engineering Series |
2009, Volume 9, Issue 2, Pages 49-60
|
Doi: Not indexed
|
Hydrological monitoring stations are placed in areas with various parameters of surrounding. We verified material layout around boreholes used for hydrological measurements with geophysical survey. There were used several geophysical methods for initial survey as dipole electromagnetic profiling, measurement of filtration potentials and electric resistivity tomography. The last one we used for repeated prospecting, which permits to assess spatio-temporally changes in electrical resitivity. We also applied neutron-neutron logging to assess moisture content in soil.
|
Download full version of article
|